Commit 0f31593
committed
Remember whether we cut power to ourselves, and re-check during boot
On the hx20 (and presumably hx30,) a design issue prevents us from
hibernating the EC properly. Therefore, every time we bring the machine
down we cut power instead of hibernating. That results in the next boot
being a complete reset.
There is code in lfw that checks whether the current boot is due to a
watchdog reset or a power-on reset and if it is, clears the image type
back to EC_IMAGE_UNKNOWN. Due to that design issue, the hx20 EC is
*always* in POR/VTR or WDT on startup.
By storing whether the last shutdown was graceful/intended and checking
it before resetting the image type, we can work around this issue.1 parent 787200e commit 0f31593