Suggestion on how to read from two Slaves at the same time #8
Description
Hello,
i have an inverter (fronius) and a smart meter.
The smart meter itself is read through the inverter with no problem.
Sometimes, though, i have a AsyncTCP kernel panic fault (i assume it is from Async lib)
My "read" function is the following
for (uint8_t i = 0; i < _numberfroniusRegisters; i++) {
uint16_t packetId = _fronius.readHoldingRegisters(_froniusRegisters[i].address, _froniusRegisters[i].length);
if (packetId > 0) {
_froniusRegisters[i].packetId = packetId;
} else {
Serial.print("reading Primo error\n");
}
}
delay(500); // test
for (uint8_t i = 0; i < _numbersmartMeterRegisters; i++) {
uint16_t packetId = _smartMeter.readHoldingRegisters(_smartMeterRegisters[i].address, _smartMeterRegisters[i].length);
if (packetId > 0) {
_smartMeterRegisters[i].packetId = packetId;
} else {
Serial.print("reading Smart Meter error\n");
}
}
the onData() and onError() definition are inside the class init and are something like this
_fronius.onData([&](uint16_t packet, uint8_t slave, esp32Modbus::FunctionCode fc, uint8_t* data, uint16_t len) {
for (uint8_t i = 0; i < _numberfroniusRegisters; ++i) {
if (_froniusRegisters[i].packetId == packet) {
_froniusRegisters[i].packetId = 0;
if (_froniusRegisters[i].address == 40091) {
union u_tag {
uint32_t b;
float fval;
} u;
u.b = (data[0] << 24) | (data[1] << 16) | (data[2] << 8) | (data[3]);
_fronius_power = u.fval;
if (!isnan(_fronius_power)) {
_fronius_power = u.fval;
_produced_power = u.fval;
_average_fronius_power = (_average_fronius_power * idx + u.fval) / (idx + 1);
Serial.printf("_produced_power: %.2f\n", _produced_power);
Serial.printf("_average_fronius_power: %.2f\n", _average_fronius_power);
}
}
}
}
});
Do you believe that calling them sequentially like that can be the reason i have these crashes?
I will soon provide you an example of a crash
Moreover in the initialization list of my main class i have the following
, _fronius(1, { 192, 168, 188, 62 }, 502)
, _smartMeter(240, { 192, 168, 188, 62 }, 502)
is there a simpler way in order to avoid declaring two "esp32ModbusTCP" and only using one that can access two slave ids?
Can i extend the API of
uint16_t esp32ModbusTCP::readHoldingRegisters(uint16_t address, uint16_t numberRegisters) {
esp32ModbusTCPInternals::ModbusRequest* request =
new esp32ModbusTCPInternals::ModbusRequest03(_serverID, address, numberRegisters);
return _addToQueue(request);
}
to take in also the different _serverID ? But how do i change the callback in order to understand which ID the information is from?