Notifications
You must be signed in to change notification settings - Fork 9
Labels
Description
Describe the bug
Currently it is desired for the Server to be inspected after maintenance (in case of hardware changes).
Maintenance -> Initial -> Discovery
Following issue is observed:
- Server power is
Off, statusMaintenance - Maintenance completed, status
Initial - During this time before reconciliation happens, Server is powered
On - Server boots up, rejoins the cluster, is
Readyand has new pods scheduled - Server is reconciled and powered
Offfor Discovery/PXE boot to start metalprobe
We should ensure that server is not powered on after Maintenance to avoid issues with the payload.
› kg biosversion dell-poweredge-r640-2-22-2-server1-system-0
dell-poweredge-r640-2-22-2-server1system-0 2.22.2 server1-system-0 dell-poweredge-r640-2-22-2-server1-system-0 Starting OK Processing 8d
dell-poweredge-r640-2-22-2-server1-system-0 2.22.2 server1-system-0 dell-poweredge-r640-2-22-2-server1-system-0 Running OK 10 Processing 8d
While we get the update about successful completion, Server is powered on:
› kg server server1-system-0 -w
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 Off Maintenance 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 On Maintenance 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 On Maintenance 74d <<<<<<<<
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 On Initial 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 On Initial 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 On Initial 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 Off Initial 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 Off Initial 74d
server1-system-0 4c4c4544-004c-3510-8051-c3c04f565033 Dell Inc. PowerEdge R640 Off Discovery 74d
› kg biosversion dell-poweredge-r640-2-22-2-server1-system-0 -w
dell-poweredge-r640-2-22-2-server1-system-0 2.22.2 server1-system-0 dell-poweredge-r640-2-22-2-server1-system-0 Completed OK 100 Processing 8d
Sub-issues
Metadata
Metadata
Assignees
Labels
Type
Projects
Status