Skip to content

dB values seam to be incorrect on both Periodogram & Spectrogram #22

@ashley-b

Description

@ashley-b

When display a single test tone of amplitude 1.0 in the Periodogram or Spectrogram display the amplitude seams down from were it should be. 3dB down for complex and 9dB down for real signals.
It does not seam to be significantly affected by the windowing mode.
But adjusting the "Full Scale" parm fixes the the issue. eg 1.0 *sqrt(1/2) for complex bring the displayed amplitude to were i would expect.

Complex normal
complex normal
Complex adjusted
complex ajusted

Real normal
real normal
Real adjusted
real ajusted

I see this bug under the Pothos v0.7.0-g42d23cb1